View DDI Information

About this task

You can view Digital Diagnostic Interface (DDI) information, for example, port information, temperature, and voltages for DDI transceivers.

Note

Note

Transceiver support differs across hardware platforms. For information about supported parts, see the Extreme Optics website.

Procedure

  1. On the Physical Device view, select one or more ports.
  2. In the navigation pane, expand Configuration > Edit > Port.
  3. Select General.
  4. Select the DDI/SFP tab.

DDI/SFP Field Descriptions

Use the data in the following table to use the DDI/SFP tab.

Name

Description

ConnectorType

Specifies the type of connector.

SupportsDDM

Specifies if the transceiver supports DDM.

DdmStatusMask

Specifies the DDM status. A value other than ddm-ok represents a specific error.

CLEI

Specifies the Telcordia register assignment CLEI code.

VendorName

Specifies the name of the manufacturer.

VendorPartNumber

Specifies the part number for the transceiver.

Select the part number to access the technical specifications for the part.

VendorRevNumber

Specifies the manufacturer revision level for the transceiver.

VendorSN

Specifies the manufacturer serial number for the transceiver.

VendorDateCode

Specifies the manufacturer date code for the transceiver.

Wavelength

Specifies the wavelength in nm. This field is valid for optical transceivers only.

Calibration

Specifies if the calibration is internal or external.

PowerMeasure

Specifies Rx power measurement as average or OMA.

Aux1Monitoring

Specifies if auxiliary monitoring is implemented for the transceiver.

Aux2Monitoring

Specifies if auxiliary monitoring is implemented for the transceiver.

TemperatureLowAlarmThreshold

Specifies the low alarm threshold in degrees Celsius.

TemperatureLowWarningThreshold

Specifies the low warning threshold in degrees Celsius.

Temperature

Specifies the current temperature in degrees Celsius of the transceiver.

TemperatureHighWarningThreshold

Specifies the high warning threshold in degrees Celsius.

TemperatureHighAlarmThreshold

Specifies the high alarm threshold in degrees Celsius.

TemperatureStatus

Specifies if any temperature thresholds were exceeded.

VoltageLowAlarmThreshold

Specifies the low alarm threshold in volts.

VoltageLowWarningThreshold

Specifies the low warning threshold in volts.

Voltage

Specifies the current voltage in volts.

VoltageHighWarningThreshold

Specifies the high warning threshold in volts.

VoltageHighAlarmThreshold

Specifies the high alarm threshold in volts.

VoltageStatus

Specifies if any voltage thresholds were exceeded.

BiasLowAlarmThreshold

Specifies the bias current low alarm threshold in mA.

BiasLowWarningThreshold

Specifies the bias current low warning threshold in mA.

Bias

Specifies the laser bias current in mA.

BiasHighWarningThreshold

Specifies the bias current high warning threshold in mA.

BiasHighAlarmThreshold

Specifies the bias current high alarm threshold in mA.

BiasStatus

Specifies if any bias thresholds were exceeded.

TxPowerLowAlarmThreshold

Specifies the low alarm threshold in dBm for the Tx power.

TxPowerLowWarningThreshold

Specifies the low warning threshold in dBm for the Tx power.

TxPower

Specifies the current Tx power in dBm.

TxPowerHighWarningThreshold

Specifies the high warning threshold in dBm for the Tx power.

TxPowerHighAlarmThreshold

Specifies the high alarm threshold in dBm for the Tx power.

TxPowerStatus

Specifies if any Tx power thresholds were exceeded.

RxPowerLowAlarmThreshold

Specifies the low alarm threshold in dBm for the Rx power.

RxPowerLowWarningThreshold

Specifies the low warning threshold in dBm for the Rx power.

RxPower

Specifies the current Rx power in dBm.

RxPowerHighWarningThreshold

Specifies the high warning threshold in dBm for the Rx power.

RxPowerHighAlarmThreshold

Specifies the high alarm threshold in dBm for the Rx power.

RxPowerStatus

Specifies if any Rx power thresholds were exceeded.

Aux1LowAlarmThreshold

Specifies the low alarm threshold auxiliary 1 reading.

Aux1LowWarningThreshold

Specifies the low warning threshold auxiliary 1 reading.

Aux1

Specifies the current auxiliary 1 reading.

Aux1HighWarningThreshold

Specifies the high warning threshold auxiliary 1 reading.

Aux1HighAlarmThreshold

Specifies the high alarm threshold auxiliary 1 reading.

Aux1Status

Specifies if any auxiliary 1 thresholds were exceeded.

Aux2LowAlarmThreshold

Specifies the low alarm threshold auxiliary 2 reading.

Aux2LowWarningThreshold

Specifies the low warning threshold auxiliary 2 reading.

Aux2

Specifies the current auxiliary 2 reading.

Aux2HighWarningThreshold

Specifies the high warning threshold auxiliary 2 reading.

Aux2HighAlarmThreshold

Specifies the high alarm threshold auxiliary 2 reading.

Aux2Status

Specifies if any auxiliary 2 thresholds were exceeded.

PowerOnCounter

Tracks the power-on-life of the part. This value increments by 1 every 48 hours of consecutive power. This value is never decremented or cleared.

If you remove or reinsert the part, reset or reboot the chassis, reset the slot, or channelize or dechannelize the port, then the 48-hour time period restarts.

TxDdmInitial

Specifies the Tx dB from low alarm, which is the difference between the TxPower dBm and the TxPower low alarm. The host provides the value after the first 48 consecutive hours of operation.

TxDdmLastGasp

Specifies the last gasp of Tx dB from low alarm. The host updates this value every 48 hours.

RxDdmInitial

Specifies the Rx dB from low alarm, which is the difference between the RxPower dBm and the RxPower low alarm. The host provides the value after the first 48 consecutive hours of operation after a power cycle.

RxDdmLastGasp

Specifies the last gasp of Rx dB from low alarm. The host updates this value every 48 hours.

ExtremeExtraFeatures

Specifies if the device supports the extra Extreme Networks features.

Note

Note

  1. Threshold and actual values for TxBias, TxPower, and RxPower are provided for all four channels in QSFP+ and QSFP28 optical transceivers.

  2. Auxiliary monitoring does not apply to QSFP+s or QSFP28s.